BPZGP - IVY GREEN QUICK DRY SPRAY ENAMEL, 55-305

  • MSDS: BPZGP
  • Manufacturer: PPG INDUSTRIES INC
  • Product Name: IVY GREEN QUICK DRY SPRAY ENAMEL, 55-305
  • National Stock Number: 8010-00N034403
Product Identification

Product ID:IVY GREEN QUICK DRY SPRAY ENAMEL, 55-305
MSDS Date:06/16/1992
FSC:8010
NIIN:00N034403
MSDS Number: BPZGP

Responsible Party
PPG INDUSTRIES INC
4325 ROSANNA DRIVE
ALLISON PARK, PA 15101
US

Emergency Phone: 412-492-5555; 304-843-1300

Info Phone: 216-572-6111; 800-441-9695

Cage: 47695

Contractor
PPG INDUSTRIES INC
PITTSBURGH, PA 15272 US

Telephone: 1-800-245-2974 (CAL HYPO)

Cage: 47695

Ingredients

2-BUTANONE; (METHYL ETHYL KETONE) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 10-15%

OSHA PEL 200 PPM;300 STEL

ACGIH TLV: 200 PPM;300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ACETONE (SARA III)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 20-25%

OSHA PEL 1000PPM

ACGIH TLV: 750PPM/1000STEL;9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


XYLENE (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 20-25%

OSHA PEL 100 PPM;150 STEL

ACGIH TLV: 100 PPM;150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 10-15%

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT


PROPANE, 2-METHYL-; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 10-15%


FILM FORMERS, RESINS, AND ADDITIVES

Fraction By Weight: 15-20%


ARE CONDITIONS ASSOCIATED WITH EXCESSIVE

RTECS: 9999999ZZ


CONTROL CENTER, EMERG ROOM/MD IMMED; HAVE

RTECS: 9999999ZZ


CAREFULLY TO DETERMINE TYPE OF AIRBORNE CONTAM

RTECS: 9999999ZZ


SUGGESTED EXPOS LIM, LEL BELOW STATED LIM, & TO REMOVE

RTECS: 9999999ZZ


SURFACES COATED WITH THIS PRODUCT.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:HARMFUL/FATAL IF INGEST.
EYE:CAUSES IRRIT. SKIN:MAY CAUSE MODERATE IRRIT. INHAL:VAP & SPRAY
MIST MAY BE HARMFUL. VAP IRRIT EYES, NOSE & THROAT. RPTD EXPOS TO
HIGH VAP CONC MAY CAUSE IRRIT OF RESP SYS & PERMANENT BRAIN &
NERVOUS SYS DMG. INTENTIONAL MISUSE BY DELIBERATELY CONC & INHAL
(EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CAN BE HARMFUL/FATAL. CHRONIC:AVOID
LONG TERM & RPTD CONT. EYE WATERING, HDCH, NAUS, DIZZ & LOSS OF
COORDINATION ARE INDICATIONS THAT SOLV LEV ARE TOO HIGH. REDNESS,
ITCHING, BURNING SENSATIO N & VISUAL DISTURBANCES MAY INDICATE
EXCESS EYE CONT. DRYNESS, ITCHING, CRACKING, BURNING, REDNESS &
SWELLING (ING 7)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT. EYE:FLUSH IMMED W/PLENTY OF WATER
FOR AT LEAST 15 MIN. SKIN:FLUSH IMMED W/PLENTY OF WATER, FOLLOWED
BY WATERLESS HAND CLEANER & SOAP & WATER IF MATL APPEARS TO ADHERE
TO SK IN. INHAL:REMOVE TO FRESH AIR. APPLY ARTIF RESP & OTHER
SUPPORTIVE MEASURES AS REQ. OTHER:IF INGEST, ANY TYPE OF
OVEREXPOS/SYMPS OF OVEREXP OCCUR DURING/FOLLOWING USE OF PROD, CONT
POIS (ING 8)

Fire Fighting

Flash Point Method:PMCC
Flash Point:15.0F,-9.4C
Lower Limits:2.3%
Extinguishing Media:USE NFPA CLASS B EXTING (CO*2, DRY CHEM/UNIVERSAL
AQUEOUS FILM FORMING FOAM) DESIGNED TO EXTING NFPA CLASS IA
(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. WATER SPRAY MAY BE USED TO COOL CLSD
CONTRS TO PREV PRESS BUILD-UP & (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELECT EQUIP, SPARKS & OPEN FLAMES. CLSD CONTRS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT. DO NOT APPLY ON (SUPDAT)

Accidental Release

Spill Release Procedures:PROVIDE MAX VENT. ONLY PERSONNEL EQUIPPED
W/PROPER RESP & SKIN & EYE PROT SHOULD BE PERMITTED IN AREA. REMOVE
ALL SOURCES OF IGNITION. TAKE UP SPILLED MATL W/SAWDUST,
VERMICULITE/OTHER ABSORB MATL & P LACE INTO CONTRS FOR DISP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDING DESIGNED AND PROTECTED FOR STORAGE OF NFPA
CLASS IA FLAMMABLE LIQUIDS.
Other Precautions:IF THIS MATERIAL IS PART OF A MULTIPLE COMPONENT
COATING SYSTEM, READ MSDS(S) FOR OTHER COMPONENT OR COMPONENTS
BEFORE BLENDING AS RESULTING MIXTURE MAY HAVE HAZARDS OF ALL OF ITS
PARTS.

Exposure Controls

Respiratory Protection:OVEREXPOS TO VAPS MAY BE PREVENTED BY ENSURING
VENT CONTROLS, VAP EXHAUST/FRESH AIR ENTRY. NIOSH/MSHA APPRVD
(TC-23C-) AIR PURIFYING/AIR SUPPLED (TC-19C-) RESP MAY ALSO REDUCE
EXPOS. READ RESP MFR'S I NSTRUCTIONS & LITERATURE (ING 9)
Ventilation:PROVIDE GENERAL DILUTION/LOC EXHAUST VENT IN VOLUME &
PATTERN TO KEEP CONC OF INGRED LISTED BELOW LOWEST (ING 10)
Protective Gloves:NITRILE RUBBER/NEOPRENE RUBBER GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FCSHLD.
Other Protective Equipment:IMPERMEABLE APRON.
Work Hygienic Practices:CLEAN OR DISCARD CONTAMINATED CLOTHING AND
SHOES.
Supplemental Safety and Health
EXTING MEDIA:FLAMM LIQ FIRES. FIRE FIGHT PROC:POSS AUTOIGNIT/EXPLOS
WHEN EXPOSED TO EXTREME HEAT. IF WATER IS USED, FOG NOZZ ARE PREF.
EXPLOS HAZ:HOT SURF. TOX GASES MAY FORM WHEN PROD IS CONTACTED BY
FLAME/HOT SURF. AEROSOL-CONTRS HOLD EXTREMELY FLAMM GAS & FLAMM LIQ
UNDER PRESS.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:>-56F,>-49C
Vapor Pres:59.8
Vapor Density:HVR/AIR
Spec Gravity:0.76
Evaporation Rate & Reference:399 (BUTYL ACETATE = 100)
Solubility in Water:22.6%
Appearance and Odor:PRESS CAN CONTAINING PAINT & PROPELLANTS W/ODOR
CHARACTERISTIC OF SOLV LISTED.
Percent Volatiles by Volume:85.80

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG ALKALIES, STRONG MINERAL ACIDS OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY PRODUCE HAZ DECOMP PRODS WHEN
HEATED. WELDING, BRAZING/FLAME CUTTING ON SURF COATED W/ PROD MAY
PRODUCE CO FUMES.

Disposal

Waste Disposal Methods:WASTE MATERIAL MUST BE DISPOSED OF IN ACCORDANCE
WITH FEDERAL, STATE, PROVINCIAL AND LOCAL ENVIRONMENTAL CONTROL
REGULATIONS. EMPTY CONTAINERS SHOULD BE RECYCLED OR DISPOSED OF
THROUGH AN APPORVED WAS TE MANAGEMENT FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.